Detailed Information of Temperature Rise High Current Test Equipment:



HNDL10000 High Current Temperature Rise Test Equipment 

1. Environmental Conditions 

a: Temperature Conditions: Working environment -10℃ to +60℃ 

b: Humidity Conditions: Relative humidity ≤70% 

c: Altitude: ≤5000 meters 

1) Input AC 50Hz, 380V±10%. Rated capacity: 360KVA (determined according to customer specifications) 

2) Can output three-phase AC high current from 0 to 6000A in a balanced manner (determined according to customer specifications); each current can be smoothly and continuously adjusted, with accuracy higher than 0.5 level; the output current is a standard sine wave with minimal burrs, better than the standard required by the power system, with a ripple factor less than 3%. The phase angles between phases are 120 degrees. 

3) Output current mode: true RMS continuously adjustable, with accuracy and stability within the output current range, and ensuring 24-hour operation at the upper limit of temperature rise. 

4) Current stability: 0.2%, the display of true RMS three-phase balance is simple and easy to operate, ensuring adjustment time ≤10 minutes. 

5) Current waveform distortion THD 1% design standard is far higher than the national standard "GB14048.2-14". 

6) Protection settings: overcurrent, overvoltage 

7) Insulation withstand voltage 1800/AC 1min, insulation class: Class B 

8) Can measure the current action time of the tested element, and can synchronously record and lock the action time. 

The special three-phase high current generator for temperature rise is specially designed and manufactured for power departments and industrial and mining enterprises in electrical equipment tests such as: various busway, switches, current transformers, and other electrical equipment for current load tests and temperature rise tests. 

This series of products adopts integrated or split structure depending on product volume and weight. The thermal relay calibrator has stepless adjustment of output current, uses 0.1 level standard transformer, digital display, balanced current rise, large load variation range, reliable operation, simple operation, and safety. The thermal relay tester is an ideal equipment for current rise or temperature rise tests in industrial and mining enterprises. 

Main technical parameters: 

1. Power supply voltage: 380V 50HZ 

2. Voltage regulator capacity: 100KVA

3. Main unit capacity: 120KVA 

4. Input current: 400A 

5. Output current: 10000A 

Operating environment: 

1. Ambient temperature: -10℃ to 40℃ 

2. The product should be free from gases, vapors, chemical dust, dirt, and other places that seriously affect transformer insulation. 

3. Working power supply: 220V/380V ±10% 50HZ 

Usage methods and precautions: 

1. The instrument must be properly grounded. 

2. Connect the power supply, connect the output terminal of the control console to the input terminal of the generator, connect the meter to the meter, turn on the air switch, and the current generator is ready for current rise. 

3. Rotate the voltage regulator evenly clockwise, pay attention to the output current indication on the control console, until the required high current is reached. 

4. During the test, once abnormal conditions are found, the relay protection calibrator should immediately cut off the air switch power supply, find out the cause, and then conduct the test. 

5. After the test, the voltage regulator must be returned to zero, press the air switch to cut off the power supply, cut off the working power supply, and remove the test wiring in the reverse direction to ensure safety. HNDL10000 High Current Temperature Rise Test Equipment 



 