Capacitor Reactive Power



0 ~ 20.00Mvar



Error



±1%



Capacitor Active Power



0 ~ 20.00kW



Error



±1%



Capacitor Dissipation Factor



0 ~ 20.00%



Error



±1%



Capacitor Resistance Component



0 ~ 10.00MΩ



Error



±1%




























Inductance Measurement Range



Error



0.10mH ~ 0.200H



±0.5%



2.000H ~ 20.00H



±0.5%



20.00H ~ 200.0H



±0.5%



200.0H ~ 2000.H



±0.5%
































Inductor Reactive Power



0 ~ 20.00Mvar



Error



±1%



Inductor Active Power



0 ~ 20.00kW



Error



±1%



Inductor Dissipation Factor



0 ~ 20.00%



Error



±1%



Inductor Resistance Component



0 ~ 10.00MΩ



Error



±1%




Clamp Sensor Measurement Range and Error (Component)















Current Measurement Range (AC)



Error



0.000mA ~ 50.00A



±0.2%



 




Product Features:



(1) Automatic range conversion;



(2) Stores 2000 test data;



(3) Large screen LCD (320×240 LCD) display, Chinese menu operation prompts;



(4) Realize simultaneous display of waveform and measurement processing data on the same screen, making the test process more intuitive;



(5) Has setting, calibration and debugging functions.



 It has the characteristics of small measurement workload, quick and simple operation, stable performance, accurate measurement, high fault detection rate; it can also measure the inductance of reactors, discharge resistance measurement function, measure the current and capacitance of coupling capacitors under live conditions, calculate the capacity of the measured capacitance; synchronously display voltage and current waveforms and phase; automatic range conversion, data storage; large screen LCD display, Chinese output, and with printing.



Working Principle:



Due to the use of standard capacitor and tested capacitor synchronous sampling technology, it is not affected by power supply voltage fluctuations; in addition, the measurement process is fully automatic, avoiding errors caused by manual operation, so it has the characteristics of good stability, good repeatability, accuracy and reliability.