Functional Features



● Automatic range conversion;



● Storage of 7168 test data points;



● Large screen LCD (320×240 LCD) display, with Chinese menu operation prompts;



● Simultaneous display of waveform and measurement processing data on the same screen, making the testing process more intuitive;



● Equipped with setting, calibration, and debugging functions.



Technical Parameters



● Capacitance range: 0.2μF~2,000μF;



Capacity range: 5~20,000 kvar;



Measurement accuracy: 0.2μF~2μF ±1% reading ±0.02μF;



2μF~2,000μF ±1% reading ±2 digits;



● Inductance range: 1mH~9.99H; Measurement accuracy: ±1.5% reading ±2 digits



● Output measurement voltage: AC 26V/500VA; 50Hz;



● Display method: Large screen LCD full Chinese output, TPμp-40 panel-type thermal printer



● Dimensions / Weight: 370×370×220 mm / 16 kg



● Working conditions:



a. Ambient temperature: 0℃ ~ +40℃, relative humidity: ≤90%



b. Power supply: AC 220V±10%; 50Hz;