Series Resonance Withstand Voltage Equipment
Series resonance withstand voltage equipment adopts the method of adjusting the frequency of the power supply, so that the reactor and the tested capacitor achieve resonance, obtaining high voltage and large current on the tested object. It is a new method and trend in high-voltage testing, and has been widely applied both domestically and internationally.
Series resonance withstand voltage equipment consists of a frequency-modulated and voltage-regulated power supply, an excitation transformer, a reactor, and a capacitive voltage divider.
Variable frequency resonance, variable frequency series resonance, series resonance, series resonance transformer, series resonance test equipment, cable withstand voltage series resonance device, series resonance withstand voltage equipment
Technical Parameters
| Rated Output Voltage | 0~220kV (AC RMS) and below |
| Output Frequency | 30~300Hz |
| Resonant Voltage Waveform | Pure sine wave, waveform distortion rate ≤1.0% |
| Full Load Working Time | Continuous working time 60min |
| System Quality Factor | ≥20 at maximum load |
| Frequency Adjustment Fineness | 0.1Hz |
| Instability | ≤0.01% |
| Working Power Supply | Single-phase 220V or three-phase 380V±10%, power frequency 50Hz±5% |
Note:
1. The product appearance is subject to the actual product. If technical parameters and models change, no separate notice will be given. Any unauthorized use or copying will be prosecuted.
2. For more information about Huatian products, please visit Product Center . Service hotline: 400-8855-448
Product Characteristics
-
1. The number of cables used at 35kV and below voltage levels is large, and the test workload is heavy. Therefore, this type of withstand voltage test device is small in size, light in weight, and the portable cable withstand voltage test system was born.
-
2. This system requires that the weight of components that can be moved on site by a single person does not exceed 30kg, and the weight of components that can be moved by two people does not exceed 60kg, suitable for on-site handling.
-
3. The power supply uses 220V single-phase or 380V single power supply, convenient for on-site power access.
-
4. The reactor part adopts dry-type epoxy casting, which is beautiful and reliable, suitable for various cable requirements.
-
5. For cable withstand voltage tests at 110kV and above voltage levels, oil-immersed reactors are used. When the single component weight exceeds 100kg, our company's special small electric crane can be optionally equipped