DC High Voltage Generator 120KV 60KV/2mA 5mA 10mA for Qualification Detailed Test Operation
1. Manual Boost Mode
After power-on, enter the main menu, rotate the setting control lever to move the cursor to the "Manual Boost" option, click the control lever to enter the manual mode parameter setting interface. After setting various parameters according to the specific test requirements, you can enter the boost interface. First press the high voltage on button, after the red light turns on, rotate the knob. When the voltage rises to the set test voltage value, the timer starts timing. After timing is completed, the system will automatically reduce the voltage to zero, then a test record save dialog box pops up. After making a selection, the test is completed; if the voltage does not reach the set test voltage value, press the 0.75UDC-1mA button, the system will automatically reduce the voltage to 0.75 times the current voltage value, then count down with the set pressurization time. After timing is completed, the system automatically reduces the voltage to zero, then a test record save dialog box pops up. After making a selection, the test is completed.
2. Automatic Boost Mode
After power-on, enter the main menu, rotate the setting control lever to move the cursor to the "Automatic Boost" option, click the control lever to enter the automatic mode parameter setting interface. After setting various parameters according to the specific test requirements, you can enter the boost interface. At this time, after pressing the high voltage on button, the system will start automatic boosting. After rising to the set test voltage value, it stabilizes the voltage and starts timing. After timing is completed, the system will automatically reduce the voltage to zero, then a test record save dialog box pops up. After making a selection, the test is completed.
DC High Voltage Generator 120KV60KV/2mA 5mA 10mA for Qualification Product Specifications
|
Specification Technical Parameters |
60/2-10 |
120/2-10 |
200/2-10 |
250/2-5 |
200/300 3/2 |
Other Levels |
|
Output Voltage (kV) |
60 |
120 |
200 |
250 |
200/300 |
600~800kV etc. customized upon contract. |
|
Output Current (mA) |
2-10 |
2-10 |
2-10 |
2-5 |
2-5 |
|
|
Output Power (W) |
120-600 |
240-1200 |
400-2000 |
500-1250 |
600 |
|
|
Charging Current (mA) |
3.0 |
3.0 |
3.0 |
3.0 |
4.5/3.0 |
|
|
Chassis Weight (kg) |
4.3 |
4.3 |
4.4 |
4.5 |
8.1 |
|
|
Voltage Doubler Cylinder Height (mm) |
Φ80 ×500 |
Φ80 ×770 |
Φ110 ×770 |
Φ110 ×820 |
Φ110 ×1350 |
|
|
Voltage Doubler Weight (kg) |
6.3 |
9.8 |
12 |
7.6 |
12.6 |
Equipment Completeness:
1. High voltage generator main unit 1 unit
2. Power operation box 1 unit
3. Test leads 1 set
4. Digital microammeter 1 piece
5. Telescopic discharge rod 1 piece
6. Power cord 1 piece
7. Fuse 3 pieces
8. Product instruction manual 1 copy
9. Product certificate (warranty card) 1 copy